Scientific Paper
Site-specific imprinting of dengue virus non-structural 1 antigen on a polydopamine-based sensing film for early detection and prognosis of dengue
Abstract
Serum levels of dengue virus (DENV) non-structural 1 (NS1) antigen can serve as a valuable prognostic indicator of severe dengue infections. A quartz crystal microbalance (QCM)-based biosensor with a biomimetic recognition element was designed to quantitatively detect DENV NS1 as an early disease biomarker. To mitigate the reliance on costly viral antigens during the molecular imprinting process, a synthetic peptide mimicking a DENV NS1 epitope was used as a surrogate template for the synthesis of an epitope-imprinted polydopamine (EMIPDA) sensing film on the biosensor surface. The maximal frequency shift for DENV NS1 was obtained with an EMIPDA film synthesised using 5 mg mL⁻¹ of dopamine monomer and 0.5 mg mL⁻¹ of peptide template. The EMIPDA-QCM biosensor achieved low detection and quantitation limits of 0.091 μg mL⁻¹ and 0.436 μg mL⁻¹, respectively, allowing acute-phase detection of dengue and prognosis of the disease progression. The EMIPDA-QCM biosensor exhibited remarkable selectivity with up to 68-fold larger frequency responses towards DENV NS1 compared to a major serum protein. The site-specific imprinting approach not only enhanced the biosensing performance but also enabled a 26-fold cost reduction for biosensor functionalisation, providing a cost-effective strategy for label-free biosensing of the dengue biomarker via the biopolymer film.
Abstract reproduced from the published article under its CC BY 4.0 licence; copyright remains with the authors.
Related work.
- MULTIPLEXED BIOSENSOR USING QUARTZ-ON-SILICON MICRO-ACOUSTIC (QSIM) TECHNOLOGY FOR IN-VITRO LABEL-FREE INVESTIGATION OF HEMOSTASIS 2023
- Evaluation of Dynamic Viscosity in the 10 MHz Range Using a General-Purpose Quartz Crystal Microbalance 2022
- Solvent effects of N,N-dimethylformamide and methanol on mass spectrometry imaging by tapping-mode scanning probe electrospray ionization 2023
- Rheology of the Electric Double Layer in Electrolyte Solutions 2020
- QCM sensörlerinin partikül madde konsantrasyonunu ölçmek için geliştirilmesi 2024
- Effects of model membranes on lysozyme amyloid aggregation 2023
New openQCM papers, by email.
A selection of new publications measured with openQCM, with software releases and application notes. A few emails a year.
Browse all papers.
Hundreds of peer-reviewed publications cite openQCM. Search full-text and filter by instrument, year, journal or topic.