Scientific Paper
Rapid Screening of Vapor Uptake by Ultra-Thin Polymer Films Using Surface Plasmon Resonance and Quartz Crystal Microbalance with Dissipation Monitoring
Abstract
Abstract Volatile emissions can be efficiently reduced by membrane separation processes. Selecting the most adequate membrane polymer can be a time and resource‐intensive screening process. It is demonstrated that surface‐sensitive techniques such as the quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) can be valuable tools to significantly cut down on the time needed to characterize and quantify vapor‐polymer interactions. Both techniques are shown to be highly complementary. QCM allows also obtaining qualitative data on changes in the polymer viscoelasticity upon vapor sorption which ultimately might permit a correlation with the mechanical membrane stability.
Abstract reproduced from the published article under its CC BY 4.0 licence; copyright remains with the authors.
Related work.
- Electrophoresis and Quartz Crystal Microbalance Instrumentation to Sense Nanoplastics in Water 2024
- A QCM-Based Device for Neurodegenerative Diseases Detection in Human Perspiration 2024
- Most common sources of pollutants in GLAMs & Assessment of main challenges for an efficient IAQ control:Deliverable 4.1 2025
- Chitosan/Sn@C composite nanofiber coatings for QCM-based humidity sensing 2026
- Aptamer-molecularly imprinted polymer sensors for the detection of bacteria in water 2025
- MoO3 Coated Quartz Crystal Microbalance as a Room Temperature Ammonia Sensing Platform 2025
New openQCM papers, by email.
A selection of new publications measured with openQCM, with software releases and application notes. A few emails a year.
Browse all papers.
Hundreds of peer-reviewed publications cite openQCM. Search full-text and filter by instrument, year, journal or topic.