openQCM Store Talk with us
03 / The bibliographyThe openQCM JournalopenQCM / Scientific paper
Store Talk with us

Scientific Paper

Signal amplification of a quartz crystal microbalance immunosensor by gold nanoparticles-polyethyleneimine for hepatitis B biomarker detection

Cover image for Signal amplification of a quartz crystal microbalance immunosensor by gold nanoparticles-polyethyleneimine for hepatitis B biomarker detection
Journal article 2023

Zahra Saffari, Reza Ahangari Cohan, Mina Sepahi, Mahdi Sadeqi, Mehdi Khoobi, Mojtaba Hamidi Fard, Amir Ghavidel, Fahimeh Bagheri Amiri, Mohammad Reza Aghasadeghi, Dariush Norouzian

Scientific Reports, 13 (1), 21851, 2023

View at publisher ↗ Full text ↗

DOI 10.1038/s41598-023-48766-2

Abstract

The procedures currently used for hepatitis B (HB) detection are not suitable for screening, clinical diagnosis, and point-of-care testing (POCT). Therefore, we developed and tested a QCM-based immunosensor by surface modification with AuNP-PEIs to amplify the signal and provide an oriented-immobilization surface. The AuNP-PEIs were characterized by ICP-Mass, UV/Vis, DLS, FE-SEM, and ATR-FTIR. After coating AuNP-PEIs on the gold electrode surface, anti-HBsAg antibodies were immobilized using NHS/EDC chemistry based on response surface methodology (RSM) optimization. The efficiency of the immunosensor was assessed by human sera and data were compared to gold-standard ELISA using receiver-operating-characteristic (ROC) analysis. FE-SEM, AFM, EDS, and EDS mapping confirmed AuNP-PEIs are homogeneously distributed on the surface with a high density and purity. After antibody immobilization, the immunosensor exhibited good recognition of HBsAg with a calibration curve of ∆F =  − 6.910e-7x + 10(R2 = 0.9905), a LOD of 1.49 ng/mL, and a LOQ of 4.52 ng/mL. The immunosensor yielded reliable and accurate results with a specificity of 100% (95% CI 47.8–100.0) and sensitivity of 100% (95% CI 96.2–100.0). In conclusion, the fabricated immunosensor has the potential as an analytic tool with high sensitivity and specificity. However, further investigations are needed to convert it to a tiny lab-on-chip for HB diagnosis in clinical samples.

More papers

Related work.

Browse all papers.

Hundreds of peer-reviewed publications cite openQCM. Search full-text and filter by instrument, year, journal or topic.

Colophon

Explore. Measure.
Publish. Repeat.

openQCM is a brand of Novaetech S.r.l. · Open hardware since 2014 · © 2026 · Cookies & Privacy Policy · Images CC BY-NC-SA 4.0, commercial use: ask us