Scientific Paper
In situ monitoring of corrosion inhibitor film formation and efficiency using simultaneous dynamic EIS and microbalance measurement
Summary
Benzotriazole adsorption on nickel in hydrochloric acid was followed with simultaneous QCM and dynamic electrochemical impedance measurements. The inhibitor binds within seconds, its impedance signature tracks the mass change, and a correction for the dissolving metal gives adsorbed masses of about 0.3 to 0.5 µg/cm² for 1 to 10 mM benzotriazole.
Summary written by the openQCM team. The original abstract is on the publisher’s page.
Related work.
- Electrophoresis and Quartz Crystal Microbalance Instrumentation to Sense Nanoplastics in Water 2024
- A QCM-Based Device for Neurodegenerative Diseases Detection in Human Perspiration 2024
- Most common sources of pollutants in GLAMs & Assessment of main challenges for an efficient IAQ control:Deliverable 4.1 2025
- Chitosan/Sn@C composite nanofiber coatings for QCM-based humidity sensing 2026
- Aptamer-molecularly imprinted polymer sensors for the detection of bacteria in water 2025
- MoO3 Coated Quartz Crystal Microbalance as a Room Temperature Ammonia Sensing Platform 2025