openQCM Store Talk with us
03 / The bibliographyThe openQCM JournalopenQCM / Scientific paper
Store Talk with us

Scientific Paper

Improving ammonia sensing performance of quartz crystal microbalance (QCM) coated with nanofibers and polyaniline (PANi) overlay

Journal article 2022

Rizky Aflaha, Henny Afiyanti, Zhafirah Nur Azizah, Hanif Khoirudin, Aditya Rianjanu, Ahmad Kusumaatmaja, Roto Roto, Kuwat Triyana

Biosensors and Bioelectronics: X, 13, 100300, 2022

View at publisher ↗ Full text ↗

DOI 10.1016/j.biosx.2022.100300

Summary

A polyaniline overlay on polyvinyl acetate nanofibres improves a QCM ammonia sensor. The best coating, with 0.05% polyaniline, reaches 0.297 Hz per ppm, about five times the plain fibres, responds in roughly half a minute and stays stable over two months, with good selectivity, reproducibility and reversibility.

Summary written by the openQCM team. The original abstract is on the publisher’s page.