Scientific Paper
Development of quartz crystal microbalance based sensor for real-time ozone monitoring
Summary
A QCM sensor coated with polybutadiene for real-time monitoring of ozone in workplaces between 10 and 100 ppbv. Tests in a controlled atmosphere examined temperature, humidity, concentration and sampling flow; the device detected 7 ppb within a few minutes and kept its sensitivity in humid air.
Summary written by the openQCM team. The original abstract is on the publisher’s page.
Related work.
- Chitosan/Sn@C composite nanofiber coatings for QCM-based humidity sensing 2026
- MoO3 Coated Quartz Crystal Microbalance as a Room Temperature Ammonia Sensing Platform 2025
- Most common sources of pollutants in GLAMs & Assessment of main challenges for an efficient IAQ control:Deliverable 4.1 2025
- Aptamer-molecularly imprinted polymer sensors for the detection of bacteria in water 2025
- Observing the Sedimentation of TiO2 Nanoparticles in Aqueous Solution Using a Quartz Crystal Microbalance with Dissipation Monitoring 2016
- Polymère à empreinte moléculaire pour la reconnaissance et l’immobilisation des bactéries photosynthétiques 2024
New openQCM papers, by email.
A selection of new publications measured with openQCM, with software releases and application notes. A few emails a year.
Browse all papers.
Hundreds of peer-reviewed publications cite openQCM. Search full-text and filter by instrument, year, journal or topic.