openQCM Store Talk with us
03 / The bibliographyThe openQCM JournalopenQCM / Scientific paper
Store Talk with us

Scientific Paper

Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation

Abstract

Liquid-phase quartz crystal microbalance (QCM) biosensors are commonly quantified using scalar readouts such as frequency shift, dissipation, or bandwidth. Although useful, these descriptors discard resonance line-shape morphology that carries additional information for quantitative inference. Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing. A passive microfluidic mixer generated controlled glycerol–water concentration gradients under constant total flow while complex impedance spectra were acquired in real time, and each sweep was parameterized using constrained Gaussian/Lorentzian models to obtain 52 physically interpretable descriptors spanning resistance, reactance, impedance magnitude, admittance components, and phase. The pipeline combines consensus outlier handling, training-fold mRMR feature ranking, and regression models evaluated under both shuffled five-fold cross-validation and a stricter temporally blocked protocol in which contiguous portions of the experiment are held out. The workflow achieved R2=0.948 under shuffled validation and R2=0.823 under seven-block temporal validation, the latter reducing prediction error by 48.4% relative to a row-matched Kanazawa frequency-shift baseline evaluated on the same sweeps. Feature-set ablation indicated that phase and conductance line-shape descriptors carry particularly strong temporally generalizable information. Applied to an experimental DNA hybridization assay in 1× PBS, the workflow reduced mean absolute percentage concentration error from 21.02% to 10.73%, a 48.9% improvement over conventional Δf calibration. Retaining resonance morphology therefore improves quantitative QCM biosensing beyond scalar frequency-shift calibration and provides an interpretable basis for AI-assisted electronic biosensors.

From the bibliography

New openQCM papers, by email.

A selection of new publications measured with openQCM, with software releases and application notes. A few emails a year.


We send a confirmation link first. Unsubscribe from any email. Privacy policy.

Browse all papers.

Hundreds of peer-reviewed publications cite openQCM. Search full-text and filter by instrument, year, journal or topic.

Colophon

Explore. Measure.
Publish. Repeat.

openQCM is a brand of Novaetech S.r.l. · Open hardware since 2014 · © 2026 · Cookies & Privacy Policy · Images CC BY-NC-SA 4.0, commercial use: ask us