# Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation

> Source page: https://openqcm.com/scientific-papers/temporally-robust-machine-learning-assisted-impedance-line-shape-analysis-for-quantitative-qcm-biosensing-with-dna-hybridization-validation
> Markdown version for AI agents and readers of plain text. Site guide: https://openqcm.com/llms.txt · Everything in one file: https://openqcm.com/llms-full.txt

- Authors: Ceyhun E. Kırımlı, Elçim Elgün, Selin Y. Tuğtağ
- Journal: Biosensors
- Year: 2026
- Volume: 16
- Pages: 574
- DOI: 10.3390/bios16100574
- Instrument used: openQCM

## Abstract

Liquid-phase quartz crystal microbalance (QCM) biosensors are commonly quantified using scalar readouts such as frequency shift, dissipation, or bandwidth. Although useful, these descriptors discard resonance line-shape morphology that carries additional information for quantitative inference. Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing. A passive microfluidic mixer generated controlled glycerol–water concentration gradients under constant total flow while complex impedance spectra were acquired in real time, and each sweep was parameterized using constrained Gaussian/Lorentzian models to obtain 52 physically interpretable descriptors spanning resistance, reactance, impedance magnitude, admittance components, and phase. The pipeline combines consensus outlier handling, training-fold mRMR feature ranking, and regression models evaluated under both shuffled five-fold cross-validation and a stricter temporally blocked protocol in which contiguous portions of the experiment are held out. The workflow achieved R2=0.948 under shuffled validation and R2=0.823 under seven-block temporal validation, the latter reducing prediction error by 48.4% relative to a row-matched Kanazawa frequency-shift baseline evaluated on the same sweeps. Feature-set ablation indicated that phase and conductance line-shape descriptors carry particularly strong temporally generalizable information. Applied to an experimental DNA hybridization assay in 1× PBS, the workflow reduced mean absolute percentage concentration error from 21.02% to 10.73%, a 48.9% improvement over conventional Δf calibration. Retaining resonance morphology therefore improves quantitative QCM biosensing beyond scalar frequency-shift calibration and provides an interpretable basis for AI-assisted electronic biosensors.

---

openQCM by Novaetech S.r.l., Pompeii, Italy · Buy: https://store.openqcm.com/ · Contact: info@openqcm.com · https://openqcm.com/contacts